PHOENIX ON-LINE UPS 2-3KV
Microprocessor control guarantees high reliability.
PWM Technology with IGBTs.
Wide Input Voltage Range.
Communication Port Selectable Smart RS-232 and Intelligent slot
for AS-400 and SNMP card.
Free Download Software from the internet for monitoring UPS status.
Optional external battery socket available for extended backup time.
Cold Start Function.
Auto self-testing system while turning on the UPS.
Modular design
Product Specifications
MODEL |
PHOENIX |
2K | 2KS* | 3K | 3KS* | |
|---|---|---|---|---|---|---|
CAPACITY |
VA/W |
2000VA
/ 1400W |
3000VA
/ 2100W |
|||
INPUT |
Voltage Range | Based
on load percentage (100%-80%/ 80%-70%/70%-60%/60%-0%) |
||||
| Low Line Transfer | 160VAC/140VAC/120VAC/110VAC
±5VAC |
|||||
| Low Line Comeback | 170VAC±5VAC |
|||||
| High Line Transfer | 300VAC±5VAC |
|||||
| High Line Comeback | 285VAC
±5VAC |
|||||
| Frequency Range | 45Hz~65Hz |
|||||
| Phase | Single
phase with ground |
|||||
| Power Factor | >0.95 |
|||||
OUTPUT |
Voltage | 220VAC/230VAC/240VAC |
||||
| Voltage Regulation | ±2% |
|||||
| Frequency (Synchronized range) | 45~65Hz |
|||||
| Frequency (Battery Mode) | 50/60Hz
± 0.2Hz |
|||||
| Current Crest Ratio | 3:01 |
|||||
| Harmonic Distortion | Tower Case | ≤3%
THD (Linear Load) <6% THD (Non-Linear Load) |
||||
| Rack Case | ≤4% THD (Linear Load) <7% THD (Non-Linear Load) |
|||||
| Output Waveform | Pure
Sinewave |
|||||
EFFICIENCY |
To AC Mode | 85% |
88% |
|||
| To Battery Mode | 83% |
83% |
||||
BATTERY |
Tower Case | Battery Type | 12V/7.2Ah | Depending on the capacity of external batteries | 12V/7.2Ah | Depending on the capacity of external batteries |
| No. of Batteries | 8 | 8 | ||||
| Backup Time | >5 minutes | >5 minutes | ||||
| Recharge Time | 5 hrs to 90% | 5 hrs to 90% | ||||
| Charging Current | 1.0A | 9.6A | 1.0A | 9.6A | ||
| Charging Voltage | 110Vdc
±0.4V |
|||||
| Rack Case | Battery Type | 12V/7.2Ah | Depending on the capacity of external batteries | 12V/7.2Ah | Depending on the capacity of external batteries | |
| No. of Batteries | 8 | 8 | ||||
| Backup Time | >5 minutes | >5 minutes | ||||
| Charging Current | 1.0A | 9.6A | 1.0A | 9.6A | ||
| Charging Voltage | 110Vdc
±0.4V |
|||||
TRANSFER TIME |
AC to DC | Zero |
||||
| Inverter to Bypass | 2.5ms
(Typical) |
|||||
INDICATOR |
Status | Load
Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault |
||||
AUDIBLE ALARM |
Battery Mode | Sounding
every 4 seconds |
||||
| Low Battery | Sounding
every seconds |
|||||
| Overload | Sounding
twice every seconds |
|||||
| Fault | Continuosly
Sounding |
|||||
DIMENSION |
Tower Case (DxWxH) mm | 460x192x340 |
||||
| Rack Case (DxWxH) mm | Rack UPS | 482.6x450x87 |
||||
| Battery Pack | 482.6x450x87 |
|||||
WEIGHT |
Tower Case (kgs) | 323kgs | 15kgs | 33kgs | 16kgs | |
| Rack Case (kgs) | 15kgs |
16kgs |
||||
ENVIRONMENT |
Operating Temperature | 0-40˚C |
||||
| Relative Humidity | 20-90%
(Non-Condensing) |
|||||
| Noise Level | <50dB
@1Meter |
|||||
INTERFACE |
Smart RS-232 | Windows
98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX,
FreeBSD, HP-UX and Mac |
||||
| SNMP (option) | Power
management from SNMP manager and web browser |
|||||
PHOENIX ON-LINE UPS