PHOENIX ON-LINE UPS 6-10KV
Microprocessor control guarantees high reliability.
PWM Technology with IGBTs.
Wide Input Voltage Range.
Communication Port Selectable Smart RS-232 and Intelligent slot
for AS-400 and SNMP card.
Free Download Software from the internet for monitoring UPS status.
Optional external battery socket available for extended backup time.
Cold Start Function.
Auto self-testing system while turning on the UPS.
Modular design
Product Specifications
MODEL |
PHOENIX |
6K | 6KS* | 10K | 10KS* | |
|---|---|---|---|---|---|---|
CAPACITY |
VA/W |
6000VA
/ 4200W |
10000VA
/ 7000W |
|||
INPUT |
Voltage Range | Low Line Transfer | 176VAC
±3VAC |
|||
| Low Line Comeback | 185VAC±VAC |
|||||
| High Line Transfer | 276VAC±5VAC |
|||||
| High Line Comeback | 266VAC
±5VAC |
|||||
| Frequency Range | 45Hz~65Hz |
|||||
| Phase | Single
phase with ground |
|||||
| Power Factor | >0.98 |
|||||
OUTPUT |
Voltage | 220VAC/230VAC/240VAC |
||||
| Voltage Regulation | ±1% |
|||||
| Frequency (Synchronized range) | 45~65Hz |
|||||
| Frequency (Battery Mode) | 60Hz
± 0.05Hz |
|||||
| Current Crest Ratio | 3:1 |
|||||
| Harmonic Distortion | Tower Case | ≤2%
THD (Linear Load) <6% THD (Non-Linear Load) |
||||
| Rack Case | ≤4% THD (Linear Load) <7% THD (Non-Linear Load) |
N/A |
||||
| Output Waveform | Pure
Sinewave |
|||||
EFFICIENCY |
To AC Mode | >88% |
||||
| To Battery Mode | ||||||
BATTERY |
Tower Case | Battery Type | 12V/7.2Ah | Depending on the capacity of external batteries | 12V/7.2Ah | Depending on the capacity of external batteries |
| No. of Batteries | 20 | 20 | ||||
| Backup Time | 8 minutes | 5 minutes | ||||
| Recharge Time | 7 hrs to 90% | 8 hrs to 90% | ||||
| Charging Current | 2A | 4.2A | 2A | 4.2A | ||
| Charging Voltage | 274Vdc
±0.5V |
|||||
| Rack Case | Battery Type | 12V/7.2Ah | N/A |
|||
| No. of Batteries | 20 | |||||
| Backup Time | >8 minutes | |||||
| Charging Current | 2A | |||||
| Charging Voltage | 274Vdc
±0.5V |
|||||
TRANSFER TIME |
AC to DC | Zero |
||||
| Inverter to Bypass | Zero |
|||||
INDICATOR |
Status | Load
Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault |
||||
AUDIBLE ALARM |
Battery Mode | Sounding
every 4 seconds |
||||
| Low Battery | Sounding
every seconds |
|||||
| Overload | Sounding
twice every seconds |
|||||
| Fault | Continuosly
Sounding |
|||||
DIMENSION |
Tower Case (DxWxH) mm | 570x260x717 |
||||
| Rack Case (DxWxH) mm | Rack UPS | 600x482.6x132 |
N/A |
|||
| Battery Pack | 600x482.6x132
|
|||||
WEIGHT |
Tower Case (kgs) | 84kgs | 35kgs | 93kgs | 38kgs | |
| Rack Case (kgs) | 37kgs |
N/A |
||||
ENVIRONMENT |
Operating Temperature | 0-40˚C |
||||
| Relative Humidity | 20-90%
(Non-Condensing) |
|||||
| Noise Level | <55dB
@1Meter |
|||||
INTERFACE |
Smart RS-232 | Windows
98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX,
FreeBSD, HP-UX and Mac |
||||
| SNMP (option) | Power
management from SNMP manager and web browser |
|||||
PHOENIX ON-LINE UPS